Seismic Network Operations

IU LCO

Las Campanas Astronomical Observatory, Chile

IU LCO commences operations on: 1998,354

Country Flag
Host: Carnegie Institution Washington
Latitude: -29.011
Longitude: -70.7
Elevation: 2300
Datalogger: Q680
Broadband: STS-1V/VBB
Accelerometer: FBA-23
Telemetry Status at the NEIC: Last Data In Less Than 10 Minutes
Station Photo Station Photo Station Photo 
Location CodeChannel CodeInstrumentFlagsSample RateDipAzimuthDepth
60BHZMetrozet M2166 VBB seismometerCG40.00-90.000.000.00
60BH2Metrozet M2166 VBB seismometerCG40.000.0090.000.00
60BH1Metrozet M2166 VBB seismometerCG40.000.000.000.00
10BHZTrillium 240 broad bandCG40.00-90.000.000.00
10BH2Trillium 240 broad bandCG40.000.0090.000.00
10BH1Trillium 240 broad bandCG40.000.000.000.00
00BHZStreckeisen STS-1VBB w/E300CG20.00-90.000.000.00
00BH2Streckeisen STS-1VBB w/E300CG20.000.0090.000.00
00BH1Streckeisen STS-1VBB w/E300CG20.000.000.000.00
20HNZKinemetrics FBA ES-T EpiSensor AccelerometerTG100.00-90.000.000.00
20HN2Kinemetrics FBA ES-T EpiSensor AccelerometerTG100.000.0090.000.00
20HN1Kinemetrics FBA ES-T EpiSensor AccelerometerTG100.000.000.000.00
10HHZTrillium 240 broad bandTG100.00-90.000.000.00
10HH2Trillium 240 broad bandTG100.000.0090.000.00
10HH1Trillium 240 broad bandTG100.000.000.000.00
60LHZMetrozet M2166 VBB seismometerCG1.00-90.000.000.00
60LH2Metrozet M2166 VBB seismometerCG1.000.0090.000.00
20LN2Kinemetrics FBA ES-T EpiSensor AccelerometerCG1.000.0090.000.00
20LN1Kinemetrics FBA ES-T EpiSensor AccelerometerCG1.000.000.000.00
60LH1Metrozet M2166 VBB seismometerCG1.000.000.000.00
31LDOCI/PAS pressure sensorCW1.000.000.000.00
30LDOlower quality chip sensor in Setra boxCW1.000.000.000.00
20LNZKinemetrics FBA ES-T EpiSensor AccelerometerCG1.00-90.000.000.00
10LHZTrillium 240 broad bandCG1.00-90.000.000.00
10LH2Trillium 240 broad bandCG1.000.0090.000.00
10LH1Trillium 240 broad bandCG1.000.000.000.00
00LHZStreckeisen STS-1VBB w/E300CG1.00-90.000.000.00
00LH2Streckeisen STS-1VBB w/E300CG1.000.0090.000.00
00LH1Streckeisen STS-1VBB w/E300CG1.000.000.000.00
60VMZMetrozet M2166 VBB seismometerCH0.100.000.000.00
60VM2Metrozet M2166 VBB seismometerCH0.100.000.000.00
60VM1Metrozet M2166 VBB seismometerCH0.100.000.000.00
60VHZMetrozet M2166 VBB seismometerCG0.10-90.000.000.00
60VH2Metrozet M2166 VBB seismometerCG0.100.0090.000.00
60VH1Metrozet M2166 VBB seismometerCG0.100.000.000.00
10VMWTrillium 240 broad bandCH0.100.000.000.00
10VMVTrillium 240 broad bandCH0.100.000.000.00
10VMUTrillium 240 broad bandCH0.100.000.000.00
10VHZTrillium 240 broad bandCG0.10-90.000.000.00
10VH2Trillium 240 broad bandCG0.100.0090.000.00
10VH1Trillium 240 broad bandCG0.100.000.000.00
00VMZStreckeisen STS-1VBB w/E300CH0.100.000.000.00
00VM2Streckeisen STS-1VBB w/E300CH0.100.000.000.00
00VM1Streckeisen STS-1VBB w/E300CH0.100.000.000.00
00VHZStreckeisen STS-1VBB w/E300CG0.10-90.000.000.00
00VH2Streckeisen STS-1VBB w/E300CG0.100.0090.000.00
00VH1Streckeisen STS-1VBB w/E300CG0.100.000.000.00
PDF, All
Image Unavailable

PDF, Last Month
Image Unavailable

PDF, Month
Image Unavailable

PDF, Current Week
Image Unavailable

PDF, Year
Image Unavailable

Heliplot
Image Unavailable
Latency
Image Unavailable

Availability, Last 365 Days
Image Unavailable

Availablity, Yearly
Image Unavailable

Availability, Last 30 Days
Image Unavailable
  1. 2014-08-04
    Upgraded to Q330 digitizer
  2. 2013-03-01
    The STS-1 is showing spiking on all components. A card on the Q680 has failed and telemetry has stopped. A replacement is on the way and a station upgrade is planned.