Seismic Network Operations

IU GNI

Garni, Armenia

IU GNI commences operations on: 1991,191

Country Flag
Host: National Survey for Seismic Protection
Latitude: 40.148
Longitude: 44.741
Elevation: 1609
Datalogger: Q330
Broadband: STS-1VBB_w/E300
Accelerometer: FBA_ES-T_EpiSensor_Accelerometer
Telemetry Status at the NEIC: Last Data In Less Than 10 Minutes
Station Photo Station Photo Station Photo 

Vault Condition: Vault is located 250 meters inside a mountain with approximately 60 meters of overburden. Seismometers are in a small room along side the tunnel and are mounted on piers. The piers are not isolated from the floor, but the floor is attached to bedrock. Entrance to the tunnel is through a building built into the hillside.

Site Geology: Alternating beds of basalt and tuff.

Location CodeChannel CodeInstrumentFlagsSample RateDipAzimuthDepth
20LN2Kinemetrics FBA ES-T EpiSensor AccelerometerCG1.000.0090.00100.00
20HN2Kinemetrics FBA ES-T EpiSensor AccelerometerTG100.000.0090.00100.00
10VH2Trillium 240 broad bandCG0.100.0090.00100.00
10LH2Trillium 240 broad bandCG1.000.0090.00100.00
10HH2Trillium 240 broad bandTG100.000.0090.00100.00
10BH2Trillium 240 broad bandCG40.000.0090.00100.00
00VH2Streckeisen STS-1VBB w/E300CG0.100.0090.00100.00
00LH2Streckeisen STS-1VBB w/E300CG1.000.0090.00100.00
00BH2Streckeisen STS-1VBB w/E300CG20.000.0090.00100.00
31LDOCI/PAS pressure sensorCW1.000.000.000.00
20LNZKinemetrics FBA ES-T EpiSensor AccelerometerCG1.00-90.000.00100.00
20LN1Kinemetrics FBA ES-T EpiSensor AccelerometerCG1.000.000.00100.00
20HNZKinemetrics FBA ES-T EpiSensor AccelerometerTG100.00-90.000.00100.00
10VMVTrillium 240 broad bandCH0.100.000.00100.00
20HN1Kinemetrics FBA ES-T EpiSensor AccelerometerTG100.000.000.00100.00
10VMWTrillium 240 broad bandCH0.100.000.00100.00
10VMUTrillium 240 broad bandCH0.100.000.00100.00
10VHZTrillium 240 broad bandCG0.10-90.000.00100.00
10VH1Trillium 240 broad bandCG0.100.000.00100.00
10LHZTrillium 240 broad bandCG1.00-90.000.00100.00
10LH1Trillium 240 broad bandCG1.000.000.00100.00
10HHZTrillium 240 broad bandTG100.00-90.000.00100.00
10HH1Trillium 240 broad bandTG100.000.000.00100.00
10BHZTrillium 240 broad bandCG40.00-90.000.00100.00
10BH1Trillium 240 broad bandCG40.000.000.00100.00
00VYZProSense PTD25-10-VH vacuum monitorCW0.100.000.00100.00
00VY2ProSense PTD25-10-VH vacuum monitorCW0.100.000.00100.00
00VY1ProSense PTD25-10-VH vacuum monitorCW0.100.000.00100.00
00VMZStreckeisen STS-1VBB w/E300CH0.100.000.00100.00
00VM2Streckeisen STS-1VBB w/E300CH0.100.000.00100.00
00VM1Streckeisen STS-1VBB w/E300CH0.100.000.00100.00
00VHZStreckeisen STS-1VBB w/E300CG0.10-90.000.00100.00
00VH1Streckeisen STS-1VBB w/E300CG0.100.000.00100.00
00LHZStreckeisen STS-1VBB w/E300CG1.00-90.000.00100.00
00LH1Streckeisen STS-1VBB w/E300CG1.000.000.00100.00
00BHZStreckeisen STS-1VBB w/E300CG20.00-90.000.00100.00
00BH1Streckeisen STS-1VBB w/E300CG20.000.000.00100.00
PDF, All
Image Unavailable

PDF, Last Month
Image Unavailable

PDF, Month
Image Unavailable

PDF, Current Week
Image Unavailable

PDF, Year
Image Unavailable

Heliplot
Image Unavailable
Latency
Image Unavailable

Availability, Last 365 Days
Image Unavailable

Availablity, Yearly
Image Unavailable

Availability, Last 30 Days
Image Unavailable
  1. 2014-05-09
    STS-1 components show LP pulsing. A new pier seems to have solved the problem.
  2. 2010-10-15
    Upgraded to Q330 digitizer.