Seismic Network Operations

IU DAV

Davao, Philippines

IU DAV commences operations on: 1994,352

Country Flag
Host: Philippine Institute of Volcanology and Seismology
Latitude: 7.07
Longitude: 125.579
Elevation: 150
Datalogger: Q330
Broadband: STS-2_High-gain
Accelerometer: FBA_ES-T_EpiSensor_Accelerometer
Telemetry Status at the NEIC: Last Data In Less Than 10 Minutes
Station Photo Station Photo Station Photo 

Vault Condition: The vault is in a limestone hillside buried with 1 meter of dirt. The pier is attached to limestone and isolated from building floor.

Site Geology: The station is located on the edge of the easter ascarpment of the Matina Anticline. The Matina Anticline consists of coralline recent limestone already metamorphosed and even crystalline.

Location CodeChannel CodeInstrumentFlagsSample RateDipAzimuthDepth
00BH1Streckeisen STS-2 Standard-gainCG40.000.000.001.00
00BH2Streckeisen STS-2 Standard-gainCG40.000.0090.001.00
00BHZStreckeisen STS-2 Standard-gainCG40.00-90.000.001.00
00LH1Streckeisen STS-2 Standard-gainCG1.000.000.001.00
00LH2Streckeisen STS-2 Standard-gainCG1.000.0090.001.00
00LHZStreckeisen STS-2 Standard-gainCG1.00-90.000.001.00
00VH1Streckeisen STS-2 Standard-gainCG0.100.000.001.00
00VH2Streckeisen STS-2 Standard-gainCG0.100.0090.001.00
00VHZStreckeisen STS-2 Standard-gainCG0.10-90.000.001.00
00VMUStreckeisen STS-2 Standard-gainCH0.100.000.001.00
00VMVStreckeisen STS-2 Standard-gainCH0.100.000.001.00
00VMWStreckeisen STS-2 Standard-gainCH0.100.000.001.00
10BH1Trillium 240 broad bandCG40.000.000.001.00
10BH2Trillium 240 broad bandCG40.000.0090.001.00
10BHZTrillium 240 broad bandCG40.00-90.000.001.00
10HH1Trillium 240 broad bandTG100.000.000.001.00
10HH2Trillium 240 broad bandTG100.000.0090.001.00
10HHZTrillium 240 broad bandTG100.00-90.000.001.00
10LH1Trillium 240 broad bandCG1.000.000.001.00
10LH2Trillium 240 broad bandCG1.000.0090.001.00
10LHZTrillium 240 broad bandCG1.00-90.000.001.00
10VH1Trillium 240 broad bandCG0.100.000.001.00
10VH2Trillium 240 broad bandCG0.100.0090.001.00
10VHZTrillium 240 broad bandCG0.10-90.000.001.00
10VMUTrillium 240 broad bandCH0.100.000.001.00
10VMVTrillium 240 broad bandCH0.100.000.001.00
10VMWTrillium 240 broad bandCH0.100.000.001.00
20HN1Kinemetrics FBA ES-T EpiSensor AccelerometerTG100.000.000.001.00
20HN2Kinemetrics FBA ES-T EpiSensor AccelerometerTG100.000.0090.001.00
20HNZKinemetrics FBA ES-T EpiSensor AccelerometerTG100.00-90.000.001.00
20LN1Kinemetrics FBA ES-T EpiSensor AccelerometerCG1.000.000.001.00
20LN2Kinemetrics FBA ES-T EpiSensor AccelerometerCG1.000.0090.001.00
20LNZKinemetrics FBA ES-T EpiSensor AccelerometerCG1.00-90.000.001.00
30LDOlower quality chip sensor in Setra boxCW1.000.000.001.00
31LDOCI/PAS pressure sensorCW1.000.000.001.00
PDF, All
Image Unavailable

PDF, Last Month
Image Unavailable

PDF, Month
Image Unavailable

PDF, Current Week
Image Unavailable

PDF, Year
Image Unavailable

Heliplot
Image Unavailable
Latency
Image Unavailable

Availability, Year
Image Unavailable

Availability, Since 1972
Image Unavailable

Availability, 2 Month
Image Unavailable
  1. Current Issues
    LN2 channel is showing high noise.
  2. 2011-07-27
    Upgraded to Q330 digitizer.