P306 Site Information Form (site log) International GPS Service See Instructions at: ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Susan Jeffries Date Prepared : 2020-05-27 Report Type : UPDATE If Update: Previous Site Log : p306_20161230.log Modified/Added Sections : (n.n,n.n,...) 1. Site Identification of the GNSS Monument Site Name : WildcatCrkCN2006 Four Character ID : P306 Monument Inscription : IERS DOMES Number : (A9) CDP Number : (A4) Monument Description : DEEP-DRILLED BRACED Height of the Monument : (m) Monument Foundation : (STEEL RODS, CONCRETE BLOCK, ROOF, etc) Foundation Depth : (m) Marker Description : NONE Date Installed : 2006-07-13 Geologic Characteristic : (BEDROCK/CLAY/CONGLOMERATE/GRAVEL/SAND/etc) Bedrock Type : (IGNEOUS/METAMORPHIC/SEDIMENTARY) Bedrock Condition : (FRESH/JOINTED/WEATHERED) Fracture Spacing : (1-10 cm/11-50 cm/51-200 cm/over 200 cm) Fault zones nearby : (YES/NO/Name of the zone) Distance/activity : (multiple lines) Additional Information : 2. Site Location Information City or Town : Oakdale State or Province : California Country : United States Tectonic Plate : North America Approximate Position (ITRF) X coordinate (m) : -2572226.6863 Y coordinate (m) : -4341705.4126 Z coordinate (m) : 3887553.8617 Latitude (N is +) : +374742.60 Longitude (E is +) : -1203840.05 Elevation (m,ellips.) : 82.5194 Additional Information : 3. GNSS Receiver Information 3.1 Receiver Type : TRIMBLE NETRS Satellite System : GPS Serial Number : 4420233976 Firmware Version : 1.1-2 19 Apr 2005 Elevation Cutoff Setting : 0 deg Date Installed : 2006-07-13T00:00Z Date Removed : 2009-12-01T21:15Z Temperature Stabiliz. : none Additional Information : (multiple lines) 3.2 Receiver Type : TRIMBLE NETRS Satellite System : GPS Serial Number : 4420233976 Firmware Version : 0.3-6 Elevation Cutoff Setting : 0 deg Date Installed : 2009-12-01T21:22Z Date Removed : 2009-12-23T13:37Z Temperature Stabiliz. : none Additional Information : (multiple lines) 3.3 Receiver Type : TRIMBLE NETRS Satellite System : GPS Serial Number : 4420233976 Firmware Version : 0.3-8 Elevation Cutoff Setting : 0 deg Date Installed : 2009-12-23T13:37Z Date Removed : 2010-03-09T19:15Z Temperature Stabiliz. : none Additional Information : (multiple lines) 3.4 Receiver Type : TRIMBLE NETRS Satellite System : GPS Serial Number : 4450241568 Firmware Version : 1.1-2 Elevation Cutoff Setting : 0 deg Date Installed : 2010-03-09T19:15Z Date Removed : 2010-04-27T21:53Z Temperature Stabiliz. : none Additional Information : (multiple lines) 3.5 Receiver Type : TRIMBLE NETRS Satellite System : GPS Serial Number : 4450241568 Firmware Version : 1.3-0 Elevation Cutoff Setting : 0 deg Date Installed : 2010-04-27T21:53Z Date Removed : 2016-08-29T11:04Z Temperature Stabiliz. : none Additional Information : (multiple lines) 3.6 Receiver Type : SEPT POLARX5 Satellite System : GPS Serial Number : 3012423 Firmware Version : 5.0.1 Elevation Cutoff Setting : deg Date Installed : 2016-08-29T11:04Z Date Removed : 2016-12-09T08:01Z Temperature Stabiliz. : none Additional Information : (multiple lines) 3.7 Receiver Type : SEPT POLARX5 Satellite System : GPS Serial Number : 3012423 Firmware Version : 5.1.0 Elevation Cutoff Setting : deg Date Installed : 2016-12-09T08:01Z Date Removed : 2018-03-21T17:11Z Temperature Stabiliz. : none Additional Information : (multiple lines) 3.8 Receiver Type : SEPT POLARX5 Satellite System : GPS Serial Number : 3012423 Firmware Version : 5.1.2 Elevation Cutoff Setting : deg Date Installed : 2018-03-21T17:11Z Date Removed : 2020-05-13T14:46Z Temperature Stabiliz. : none Additional Information : (multiple lines) 3.9 Receiver Type : SEPT POLARX5 Satellite System : GPS Serial Number : 3012423 Firmware Version : 5.3.2 Elevation Cutoff Setting : deg Date Installed : 2020-05-13T14:46Z Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : none Additional Information : (multiple lines) 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : TRM29659.00 SCIT Serial Number : 0220368161 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0083 Marker->ARP North Ecc(m) : 0 Marker->ARP East Ecc(m) : 0 Alignment from True N : deg Antenna Radome Type : SCIT Radome Serial Number : 1095 Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : 2006-07-13T00:00Z Date Removed : 2016-08-29T11:03Z Additional Information : (multiple lines) 4.2 Antenna Type : TRM59800.00 SCIT Serial Number : 5225354525 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0083 Marker->ARP North Ecc(m) : 0 Marker->ARP East Ecc(m) : 0 Alignment from True N : deg Antenna Radome Type : SCIT Radome Serial Number : 1095 Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : 2016-08-29T11:03Z Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : Effective Dates : 2006-07-13/CCYY-MM-DD Notes : (multiple lines) 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.1 Instrumentation Type : NONE Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DDThh:mmZ) Notes : (multiple lines) 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : WXT520 Manufacturer : Vaisala Serial Number : E2850013 Data Sampling Interval : Accuracy (% rel h) : Aspiration : Height Diff to Ant : Calibration date : (CCYY-MM-DD) Effective Dates : 2009-11-25/2010-02-12 Notes : (multiple lines) 8.2.1 Pressure Sensor Model : WXT520 Manufacturer : Vaisala Serial Number : E2850013 Data Sampling Interval : Accuracy : Height Diff to Ant : Calibration date : (CCYY-MM-DD) Effective Dates : 2009-11-25/2010-02-12 Notes : (multiple lines) 8.3.1 Temp. Sensor Model : WXT520 Manufacturer : Vaisala Serial Number : E2850013 Data Sampling Interval : Accuracy : Aspiration : Height Diff to Ant : Calibration date : (CCYY-MM-DD) Effective Dates : 2009-11-25/2010-02-12 Notes : (multiple lines) 8.4.1 Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.1.2 Humidity Sensor Model : WXT520 Manufacturer : Vaisala Serial Number : C4910004 Data Sampling Interval : Accuracy (% rel h) : Aspiration : Height Diff to Ant : Calibration date : (CCYY-MM-DD) Effective Dates : 2010-02-12/2010-03-10 Notes : (multiple lines) 8.2.2 Pressure Sensor Model : WXT520 Manufacturer : Vaisala Serial Number : C4910004 Data Sampling Interval : Accuracy : Height Diff to Ant : Calibration date : (CCYY-MM-DD) Effective Dates : 2010-02-12/2010-03-10 Notes : (multiple lines) 8.3.2 Temp. Sensor Model : WXT520 Manufacturer : Vaisala Serial Number : C4910004 Data Sampling Interval : Accuracy : Aspiration : Height Diff to Ant : Calibration date : (CCYY-MM-DD) Effective Dates : 2010-02-12/2010-03-10 Notes : (multiple lines) 8.4.2 Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.1.3 Humidity Sensor Model : WXT520 Manufacturer : Vaisala Serial Number : E2850013 Data Sampling Interval : Accuracy (% rel h) : Aspiration : Height Diff to Ant : Calibration date : (CCYY-MM-DD) Effective Dates : 2010-03-10/2011-01-25 Notes : (multiple lines) 8.2.3 Pressure Sensor Model : WXT520 Manufacturer : Vaisala Serial Number : E2850013 Data Sampling Interval : Accuracy : Height Diff to Ant : Calibration date : (CCYY-MM-DD) Effective Dates : 2010-03-10/2011-01-25 Notes : (multiple lines) 8.3.3 Temp. Sensor Model : WXT520 Manufacturer : Vaisala Serial Number : E2850013 Data Sampling Interval : Accuracy : Aspiration : Height Diff to Ant : Calibration date : (CCYY-MM-DD) Effective Dates : 2010-03-10/2011-01-25 Notes : (multiple lines) 8.4.3 Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.1.4 Humidity Sensor Model : WXT520 Manufacturer : Vaisala Serial Number : F2620005 Data Sampling Interval : Accuracy (% rel h) : Aspiration : Height Diff to Ant : Calibration date : (CCYY-MM-DD) Effective Dates : 2011-01-25/CCYY-MM-DD Notes : (multiple lines) 8.2.4 Pressure Sensor Model : WXT520 Manufacturer : Vaisala Serial Number : F2620005 Data Sampling Interval : Accuracy : Height Diff to Ant : Calibration date : (CCYY-MM-DD) Effective Dates : 2011-01-25/CCYY-MM-DD Notes : (multiple lines) 8.3.4 Temp. Sensor Model : WXT520 Manufacturer : Vaisala Serial Number : F2620005 Data Sampling Interval : Accuracy : Aspiration : Height Diff to Ant : Calibration date : (CCYY-MM-DD) Effective Dates : 2011-01-25/CCYY-MM-DD Notes : (multiple lines) 8.4.4 Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : UNAVCO Preferred Abbreviation : UNAVCO Mailing Address : : Boulder CO USA 80301 Primary Contact Contact Name : Karl Feaux Telephone (primary) : 303-381-7556 Telephone (secondary) : Fax : 303-381-7552 E-mail : feaux@unavco.org Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 12. Responsible Agency (if different from 11.) Agency : Preferred Abbreviation : Mailing Address : Primary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 13. More Information Primary Data Center : UNAVCO Boulder Facility Archive Secondary Data Center : URL for More Information : http://www.unavco.org Hardcopy on File Site Map : (Y or URL) Site Diagram : (Y or URL) Horizon Mask : (Y or URL) Monument Description : (Y or URL) Site Pictures : (Y or URL) Additional Information : (multiple lines) Antenna Graphics with Dimensions TRM29659.00 TRM59800.00 TRM59800.80 TRM59900.00 ----- / \ | | +-------------------------------------------------+ <-- 0.1020 TCR | | | | | | | | +-+-------------------------------------------------+-+ <-- 0.0381 +-------------------+-------------+-------------------+ <-- 0.0350 BCR | | =| | +------x------+ <-- 0.0000 BPA=ARP <-- 0.3810 -->