Seismic Network Operations

IU PMG

Port Moresby, New Guinea

IU PMG commences operations on: 1993,253

Country Flag
Host: Port Moresby Geophysical Observatory
Latitude: -9.405
Longitude: 147.16
Elevation: 90
Datalogger: Q330
Broadband: STS-1VBB_w/E300
Accelerometer: FBA_ES-T_EpiSensor_Accelerometer
Telemetry Status at the NEIC: No Data In More Than 24 Hours
Station Photo Station Photo Station Photo 

Vault Condition: The seismometer vault is a concrete room covered with earth to a depth of approximately two meters. The vault is airconditioned.

Site Geology: Eocene Chert.

Location CodeChannel CodeInstrumentFlagsSample RateDipAzimuthDepth
00VMZStreckeisen STS-1VBB w/E300CH0.100.000.000.00
00VM2Streckeisen STS-1VBB w/E300CH0.100.000.000.00
00VM1Streckeisen STS-1VBB w/E300CH0.100.000.000.00
00VHZStreckeisen STS-1VBB w/E300CG0.10-90.000.000.00
00VH2Streckeisen STS-1VBB w/E300CG0.100.0088.000.00
00VH1Streckeisen STS-1VBB w/E300CG0.100.00358.000.00
00LHZStreckeisen STS-1VBB w/E300CG1.00-90.000.000.00
00LH2Streckeisen STS-1VBB w/E300CG1.000.0088.000.00
00LH1Streckeisen STS-1VBB w/E300CG1.000.00358.000.00
00BHZStreckeisen STS-1VBB w/E300CG20.00-90.000.000.00
00BH2Streckeisen STS-1VBB w/E300CG20.000.0088.000.00
00BH1Streckeisen STS-1VBB w/E300CG20.000.00358.000.00
00VYZProSense PTD25-10-VH vacuum monitorCW0.100.000.000.00
00VY2ProSense PTD25-10-VH vacuum monitorCW0.100.000.000.00
00VY1ProSense PTD25-10-VH vacuum monitorCW0.100.000.000.00
60VMZMetrozet M2166 VBB seismometerCH0.100.000.000.00
60VM2Metrozet M2166 VBB seismometerCH0.100.000.000.00
60VM1Metrozet M2166 VBB seismometerCH0.100.000.000.00
60VHZMetrozet M2166 VBB seismometerCG0.10-90.000.000.00
60VH2Metrozet M2166 VBB seismometerCG0.100.0090.000.00
60VH1Metrozet M2166 VBB seismometerCG0.100.000.000.00
60LHZMetrozet M2166 VBB seismometerCG1.00-90.000.000.00
60LH2Metrozet M2166 VBB seismometerCG1.000.0090.000.00
60LH1Metrozet M2166 VBB seismometerCG1.000.000.000.00
60BHZMetrozet M2166 VBB seismometerCG40.00-90.000.000.00
60BH2Metrozet M2166 VBB seismometerCG40.000.0090.000.00
60BH1Metrozet M2166 VBB seismometerCG40.000.000.000.00
30LDOlower quality chip sensor in Setra boxCW1.000.000.000.00
20LNZKinemetrics FBA ES-T EpiSensor AccelerometerCG1.00-90.000.000.00
20LN2Kinemetrics FBA ES-T EpiSensor AccelerometerCG1.000.0090.000.00
20LN1Kinemetrics FBA ES-T EpiSensor AccelerometerCG1.000.000.000.00
20HNZKinemetrics FBA ES-T EpiSensor AccelerometerTG100.00-90.000.000.00
20HN2Kinemetrics FBA ES-T EpiSensor AccelerometerTG100.000.0090.000.00
20HN1Kinemetrics FBA ES-T EpiSensor AccelerometerTG100.000.000.000.00
10LHZGuralp CMG3-T SeismometerCG1.00-90.000.000.00
10LH2Guralp CMG3-T SeismometerCG1.000.0090.000.00
10LH1Guralp CMG3-T SeismometerCG1.000.000.000.00
10HHZGuralp CMG3-T SeismometerTG100.00-90.000.000.00
10HH2Guralp CMG3-T SeismometerTG100.000.0090.000.00
10HH1Guralp CMG3-T SeismometerTG100.000.000.000.00
10BHZGuralp CMG3-T SeismometerCG40.00-90.000.000.00
10VMZGuralp CMG3-T SeismometerCH0.100.000.000.00
10VM2Guralp CMG3-T SeismometerCH0.100.000.000.00
10VM1Guralp CMG3-T SeismometerCH0.100.000.000.00
10VHZGuralp CMG3-T SeismometerCG0.10-90.000.000.00
10VH2Guralp CMG3-T SeismometerCG0.100.0090.000.00
10VH1Guralp CMG3-T SeismometerCG0.100.000.000.00
10BH2Guralp CMG3-T SeismometerCG40.000.0090.000.00
10BH1Guralp CMG3-T SeismometerCG40.000.000.000.00
31LDOCI/PAS pressure sensorCW1.000.000.000.00
PDF, All
Image Unavailable

PDF, Last Month
Image Unavailable

PDF, Month
Image Unavailable

PDF, Current Week
Image Unavailable

PDF, Year
Image Unavailable

Heliplot
Image Unavailable
Latency
Image Unavailable

Availability, Last 365 Days
Image Unavailable

Availablity, Yearly
Image Unavailable

Availability, Last 30 Days
Image Unavailable
  1. 2014-06-04
    Improvements to the vault have been completed.
  2. 2013-06-06
    Seismometer vault is leaking. Repairs are under way.
  3. 2010-04-19
    Upgraded to Q330 digitizer.